Test was using and assuming that severity string starts with
capital letter (e.g. "Style"). But the strings are all lowercase
letters.
Ticket #2832 (GUI: XML version 1 test fails)
Start building each test as separate project as QtestLib tests
usually are built. This commit adds the infrastructure and moves
TranslationHandler test as own project.
Fix I did yesterday gave only filename of the project file for
function loading project file. Causing the loading failing if
not in "current" directory.
If we there is project file in the directory to check then ask
user if one wants to use the project file instead. If there are
multiple project files then just tell there are project files
and ask if user wants to continue without using them.
Ticket: #2816 (GUI regression: Interrupted checking because of too many #ifdef configurations.)
If the project file does not define paths to check then check the
project root directory (which likely is the directory where the
project file is located).
Ticket #2816 (GUI regression: Interrupted checking because of too many #ifdef configurations.)
Setting organization and program name in main() allows us to
cleanup Settings class usage. As we don't need to keep using the
one instance of Settings but can create new Settings class
whenever we need to access settings. According to the Qt
documentation creating Settings class is fast.
Use project file's location as base path when adding new paths
(checked, included or ignored) to the project. In most cases user
wants to add paths in the same project so this reduces browsing
paths considerably when adding them.
When project files support was added to the GUI there was no GUI
for them and automatic/silent loading was added. So that if the
directory contained project file with the same name (and .cppcheck
extension) then the project file was automatically loaded and used
for the checking.
This can be very confusing for the user as there is no any
indication that the project file is used. But this solution was
necessary at that time to get project file support added.
Now that we have usable GUI for the project files this automatic/
silent loading can be removed. Nobody really should be using it
anymore. And even if the automatic loading is needed one can give
the project file for the GUI using command line parameter.
The project file to check just GUI code was missing the directory
to check. This is probably due it was used originally as
"automatically" loaded project file which assumed current
directory is checked and only added some additional parameters.